    increases service life of downstream fittings and equipment
    high flow rate - owing to flow maximising design
    especially for O2 with bronze filter, meets all requirements of EIGA guidelines
    with condensate drain
    change of filter possible while installed
    every gas filter 100% tested
    72 X 205 mm, approx. 3 kg

    WITT gas filter for GOX : Best practices in Safety, with maximum Operability.
    In addition to removing contaminants, WITT’s Filter 77 – O2 drains out condensate, protects downstream
    equipment and extends service life. All designed to meet the Best practices in Safety, with maximum Operability.

    Description :
    Bronze (Cu89/Sn11) 50μ filter element
    O-Ring Elastomer FKM (FKM 938)
     -30 °C to +60 °C
    Up to 40 barg
    Connections G 3/4 F
    Length 205 mm, diameter 72 mm, mass 3.03 kg
    Type 077-010
     

    Meeting the Best Practices in Safety :
    Meets all the requirements of EIGA Guideline IGC Doc 13/12/E “Oxygen Pipeline and Piping Systems“
    Certification by BAM (German Federal Institute for Materials Research and Testing) for O2 service
    Pre-cleaned to EIGA Guideline IGC Doc 13/12/E, and ready for O2
    Withstands maximum line pressure (40 barg) even if it becomes clogged
    No velocity limitation, including during commissioning “blow-out” testing
    Not subject to a minimum thickness requirement (per Appendix D of EIGA Guideline IGC Doc 13/12/E).
     

     With maximum Operability :
    Reliable filtering performance increases service life of downstream fittings and equipment
    Condensate can be collected and removed using condensate drain
    Change of filter element possible while installed, due to user-friendly design
    High flowrates owing to its flow maximising design (please see flow curves overleaf)
    Easy to install
    Easy to maintain - the condensate should be drained at regular intervals, and the filter element should be checked regularly and replaced if necessary in accordance with Appendix F of EIGA Guideline IGC Doc 13/12/E.